![background image](http://html1.mh-extra.com/html/omron/e3nw-ect/e3nw-ect_operation-manual_741099148.webp)
A Appendices
A - 44
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
•
This object executes the Sensor initialization command for the Sensor with the unit number that is
specified by the index.
•
Set this object to 0001 hex to write data. It is always set to 0000 hex when reading data.
•
To initialize the Sensor during operation, use this command to initialize the Sensor. Do not use the
buttons on the Sensor.
•
The channel display, display blinking, emission OFF, and flashing settings are not initialized when the
Sensor is initialized.
•
This object sets the self trigger level of the Sensor with the unit number that is specified by the index.
* Items with asterisks are supported from E3NW-ECT version 1.08.
•
This object executes the Tuning with workpiece absent command for the Sensor with the unit number
that is specified by the index.
•
Set this object to 0001 hex to write data. It is always set to 0000 hex when reading data.
•
Execute the first point of 2-point tuning with workpiece absent first.
4042 + (N-1)
×
80
hex
No_01 ... 30 Sensor Initialization
Subindex 0: Number of Entries
Range: 01 hex
Unit: ---
Default: 01 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Sensor Initialization
Range: 0000 to 0001 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
4050 + (N-1)
×
80
hex
No_01 ... 30 Self Trigger Level and Scaling Setting *
Subindex 0: Number of Entries
Range: 01 hex
Unit: ---
Default: 01 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Self Trigger Level and Scaling Setting *
Range:
−
1,999 to 9,999
(F831 to 270F hex)
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (INT16)
Access: RW
PDO map: Not possible
4051 + (N-1)
×
80
hex
No_01 ... 30 Tuning with workpiece absent
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Tuning with workpiece absent IN1
Range: 0000 to 0001 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Sub-index 2: No_01 ... 30 Tuning with workpiece absent IN2
Range: 0000 to 0001 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Summary of Contents for E3NW-ECT
Page 1: ...E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual E429 E1 07...
Page 3: ...E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual Revised December 2017...
Page 4: ......
Page 170: ...Revision 2 E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual E429...
Page 171: ......