A Appendices
A - 52
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
This section describes how to mount and remove the E3NW-DS and individual Amplifiers to the DIN
Track.
Refer to "7-3 Mounting Dimensions" on page 7-9 for dimensions of each Distributed Sensor Units.
Use the following procedure to mount the Units.
1
Hook the upper portion of the Unit on the DIN Track.
2
Press the lower portion of the Unit against the DIN Track.
3
Remove the protective cap from the right side of the Distributed Sensor Unit. Then, slide
the Sensor Amplifier Units against the Distributed Sensor Unit with the tabs aligned with
the notches in the connector area. Press them together until they click into place.
4
Use the DIN Track End Plates (PFP-M) that are provided to remove any gaps between the
Units and secure them in place. Replace the protective cap that you removed in step 3 to
the Sensor Amplifier on the right end.
A-2-2
Mounting and Removing Distributed Sensor Units
Mounting Method
Push into place.
DIN Track
End Plates
Protective cap