1 Object
Dictio
nary
A
A-1-7
Manufacturer
S
pecific
Obj
e
c
ts
•
This object sets the DPC setting and number of display digits of the Sensor with the unit number that
is specified by the index.
* Items with asterisks are supported from E3NW-ECT version 1.03.
You can check the version with object index 100A hex. (Refer to "A-1-4 Communication Objects" on page A-4.)
DPC Setting
Display Digits Setting
4011 + (N-1) × 80
hex
No_01 ... 30 DPC Setting and Display Digits*
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 DPC Setting IN1 and Display Digits*
Range: 0000 hex to FFFF hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Subindex 2*: No_01 ... 30 DPC Setting IN2
Range: 0000 hex to FFFF hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Data
Setting
0000 hex
DPC OFF
0001 hex
DPC ON
0002 to FFFF hex
Not used.
Data
Setting
0000 hex
4 digits
0001 hex
3 digits
0002 hex
2 digits
0003 hex
1 digit
0004 hex
0 digit
0005 to FFFF hex
Not used.
Summary of Contents for E3NW-ECT
Page 1: ...E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual E429 E1 07...
Page 3: ...E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual Revised December 2017...
Page 4: ......
Page 170: ...Revision 2 E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual E429...
Page 171: ......