A Appendices
A - 32
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
•
Set the threshold for differential output of the unit number specified by the index.
•
This object sets the timer value 1 of the Sensor with the unit number that is specified by the index.
•
Timer value 1 is used for the ON delay or the one-shot timer.
•
The setting units for the FA0, LA0, and SA0 are 1 ms, and the setting range is 0x0001 (1) - 0x270F
(9999).
For the CA0, the settings are selected in increments of 1 (units of 0.1 ms) from 0.1 ms to 0.5 ms, in
increments of 5 (units of 0.5 ms) from 0.5 ms to 5 ms, and in increments of 10 (units of 1ms) from 5
ms to 9999 ms.
The setting range is 0x00000001Hex (1) - 0x00018696 (99990).
•
This object sets the timer value 2 of the Sensor with the unit number that is specified by the index.
•
Timer value 2 is used for the OFF delay.
•
The setting units for the FA0, LA0, and SA0 are 1 ms, and the setting range is 0x0001 (1) - 0x270F
(9999).
For the CA0, the settings are selected in increments of 1 (units of 0.1 ms) from 0.1 ms to 0.5 ms, in
increments of 5 (units of 0.5 ms) from 0.5 ms to 5 ms, and in increments of 10 (units of 1ms) from 5
ms to 9999 ms.
The setting range is 0x00000001Hex (1) - 0x00018696 (99990).
0
×
400D + (N-1)
×
80 hex
No_01 ... 30 Diffinition Function Response Time
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Diffinition Function Response Time IN1
Range: 0000 to FFFF hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Subindex 2: No_01 ... 30 Diffinition Function Response Time IN2
Range: 0000 to FFFF hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Data
Setting
0001 hex
Response Time 250
μ
S
0002 hex
Response Time 500
μ
S
0003 hex
Response Time 1 mS
0004 hex
Response Time 10 mS
0005 hex
Response Time 100 mS
400F + (N-1)
×
80 hex
No_01 ... 30 Timer Value 1
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Timer Value 1 IN1
Range: 00000001 hex to 00018696 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 4 bytes (U32)
Access: RW
PDO map: Not possible
Subindex 2: No_01 ... 30 Timer Value 1 IN2
Range: 00000001 hex to 00018696 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 4 bytes (U32)
Access: RW
PDO map: Not possible
4010 + (N-1)
×
80
hex
No_01 ... 30 Timer Value 2
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Timer Value 2 IN1
Range: 00000001 hex to 00018696 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 4 bytes (U32)
Access: RW
PDO map: Not possible
Subindex 2: No_01 ... 30 Timer Value 2 IN2
Range: 00000001 hex to 00018696 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 4 bytes (U32)
Access: RW
PDO map: Not possible
Summary of Contents for E3NW-ECT
Page 1: ...E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual E429 E1 07...
Page 3: ...E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual Revised December 2017...
Page 4: ......
Page 170: ...Revision 2 E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual E429...
Page 171: ......