A-2 U
sing
Distrib
u
te
d Sens
or Un
it
s
A
A-2-3
DS-Bus Networ
k
Wiring
Recommended Parts
E3NW-series Sensor Communication Unit
Connect a communications cable to the DS-Bus communications connector on the Sensor
Communication Unit.
Also, clamp on a ferrite core (enclosed) on the communications cable.
When you prepare a new DS-Bus connector, cut off the protrusion on one side of the connector as
shown in the following figure. The enclosed connector already has this protrusion removed.
Part
Manufacturer
Model
Communications Cable
Bando Densen Co., Ltd.
ESVC 0.5X2C black
Connecting Communications Cables and Connectors
To Distributed
Sensor Unit
D+ terminal
D− terminal
Communications
Cable
Ferrite core
Ferrule
Cut off this protrusion.
Cut off this protrusion.