A Appendices
A - 36
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
•
This object sets the hysteresis width setting of the Sensor with the unit number that is specified by the
index.
* Items with asterisks are supported from E3NW-ECT version 1.03.
You can check the version with object index 100A hex. (Refer to "A-1-4 Communication Objects" on page A-4.)
•
This object sets the Hysteresis Width 1 setting of the Sensor with the unit number that is specified by
the index.
•
FA0, LA0, SA0, or FAH0 is assigned to the hysteresis width of IN 2 of normal detection mode by
Subindex 2.
•
MA0 is assigned to the hysteresis width of normal detection mode and the low hysteresis width of
area detection mode.
•
EA
□
0, AA
□
0, or VA
□
0 is assigned to the hysteresis width of normal detection mode and the high/low
hysteresis width of area detection mode.
•
The setting range for FA0, LA0, SA0, FAH0, MA0, or EA0 is 0000 0000 to 0000 270F hex.
•
This object sets the Hysteresis Width 2 high setting of the Sensor with the unit number that is
specified by the index.
•
FA0, LA0, SA0, or FAH0 is assigned to IN1 of normal detection mode and the high/low hysteresis
width of area detection mode by Subindex 1.
4020 + (N-1)
×
80
hex
No_01 ... 30 Hysteresis Width Setting
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Hysteresis Width Setting IN1
Range: 0000 to FFFF hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Subindex 2*: No_01 ... 30 Hysteresis Width Setting IN2
Range: 0000 to FFFF hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Data
Setting
0000 hex
Standard
0001 hex
User setting
0002 to FFFF hex
Not used.
4021 + (N-1)
×
80
hex
No_01 ... 30 Hysteresis Width 1
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 IN1
Range: 0000 0000 to 05F5 E0FF hex
Unit: ---
Default: - hex
Attribute: A
Size: 4 bytes (U32)
Access: RW
PDO map: Not possible
Subindex 2: No_01 ... 30 IN2
Range: 0000 0000 to 05F5 E0FF hex
Unit: ---
Default: - hex
Attribute: A
Size: 4 bytes (U32)
Access: RW
PDO map: Not possible
4022 + (N-1)
×
80
hex
No_01 ... 30 Hysteresis Width 2
Subindex 0: Number of Entries
Range: 01 hex
Unit: ---
Default: 01 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 IN1
Range: 0000 0000 to 05F5 E0FF hex
Unit: ---
Default: - hex
Attribute: A
Size: 4 bytes (U32)
Access: RW
PDO map: Not possible
Subindex 2: No_01 ... 30 IN2
*2
Range: 0000 0000 to 05F5 E0FF hex
Unit: ---
Default: - hex
Attribute: A
Size: 4 bytes (U32)
Access: RW
PDO map: Not possible
Summary of Contents for E3NW-ECT
Page 1: ...E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual E429 E1 07...
Page 3: ...E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual Revised December 2017...
Page 4: ......
Page 170: ...Revision 2 E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual E429...
Page 171: ......