2HA/2HB
1-5-11
(5) Detaching and refitting the registration left roller
Follow the procedure below to replace the registration left roller.
Procedure
1. Remove the paper conveying unit (see page
1-5-7).
2. Remove the transfer roller (see page 1-5-
27).
3. Release the stoppers at the front and rear
side, and then remove the registration left
roller from the paper conveying unit.
4. Replace the registration left roller and refit
all the removed parts.
Figure 1-5-21
(6) Detaching and refitting the registration cleaner
Follow the procedure below to replace the registration cleaner.
Procedure
1. Remove the drum unit (see page 1-5-23).
2. Remove the screw and then the registration
guide.
Figure 1-5-22
3. Remove the screw and then the registration
cleaner.
4. Replace the registration cleaner and refit all
the removed parts.
Figure 1-5-23
Registration left roller
Stopper
Stopper
Paper conveying unit
Registration guide
Trans guide film
Registration cleaner
Summary of Contents for d-Copia 1600
Page 1: ...SERVICE MANUAL Published in October 2005 842HB110 First Edition d Copia 1600 d Copia 2000...
Page 3: ...Revision history Revision Date Replaced pages Remarks...
Page 4: ...This page is intentionally left blank...
Page 10: ...This page is intentionally left blank...
Page 14: ...2HA 2HB 1 4 30 This page is intentionally left blank...
Page 20: ...2HA 2HB 1 4 30 This page is intentionally left blank...
Page 126: ...2HA 2HB 1 4 30 This page is intentionally left blank...
Page 162: ...2HA 2HB 1 4 30 This page is intentionally left blank...
Page 180: ...2HA 2HB 1 4 30 This page is intentionally left blank...
Page 213: ...INSTALLATION GUIDE FOR THE 300 SHEET CASSETTE...
Page 220: ...INSTALLATION GUIDE FOR THE DOCUMENT PROCESSOR...
Page 231: ...INSTALLATION GUIDE FOR THE DUPLEX UNIT...
Page 239: ...INSTALLATION GUIDE FOR THE Printing System X...
Page 242: ......