![Nortel Passport 8600 Series Commissioning Download Page 62](http://html.mh-extra.com/html/nortel/passport-8600-series/passport-8600-series_commissioning_1706226062.webp)
62
Initial steps using the CLI
Configuring the time zone
Set the time zone to specify the time zone for your location and configure
settings for Daylight Saving Time (DST).
Procedure steps
Step
Action
1
Configure the time zone by using the following command:
config bootconfig tz
2
Save the changed configuration to the boot.cfg and pcmboot.cfg
files.
3
Reboot the switch.
--End--
Variable definitions
Use the data in the following table to use the
config bootconfig tz
command.
Variable
Value
dst-end
<Mm.n.d/hhmm|MMddhhmm>
Configures the ending date of DST. You
can specify the time in one of two ways:
•
Mm.n.d/hhmm
specifies an hour on
the nth occurrence of a weekday in a
month. For example,
M10.5.0/0200
means the fifth occurrence of Sunday
in the tenth month (October) at 2:00
a.m.
•
MMddhhmm
specifies a month, day,
hour, and minute. For example,
10310200
means October 31 at 2:00
a.m.
dst-name <dstname>
Configures an abbreviated name for the
local daylight saving time zone.
dstname
is the name. For example, PDT is Pacific
Daylight Time.
Nortel Ethernet Routing Switch 8600
Commissioning
NN46205-319
01.01
Standard
30 May 2008
Copyright © 2008 Nortel Networks
.
Summary of Contents for Passport 8600 Series