Commissioning verification
Variable
Value
-d
Configures ping debug mode (for
IPv4).
datasize value
Specifies the size of ping data sent
in bytes (for IPv4) (16–4076).
HostName/ipv4address/ipv6addre
ss
Specifies the host name or IPv4
(a.b.c.d) or IPv6 (x:x:x:x:x:x:x:x)
address (string length 1–256).
-I
Specifies the interval between
transmissions in seconds (1–60).
-s
Configures the continuous ping
at the interval rate defined by the
[-I]
parameter (for IPv4).
scopeid value
Specifies the circuit ID (for IPv6)
(1–9999).
-t
Specifies the no-answer timeout
value in seconds (1–120) for IPv4.
vrf <value>
Specifies the virtual router and
forwarder (VRF) name from 1–16
characters.
Using Telnet to log on to the device
Use Telnet to log on to the device and remotely manage the switch.
Procedure steps
Step
Action
1
From a PC or terminal, start a Telnet session by using the
following command:
telnet <ipv4 or ipv6 address>
2
Enter the logon and password when prompted.
--End--
Accessing the switch through the Web interface
Monitor the switch through a Web browser from anywhere on your
network. The Web interface uses a 15-minute timeout period. If no activity
occurs for 15 minutes, the system logs off the switch Web interface, and
you must re-enter the password information.