Repair
7-26
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Replacing Level Evaluator with 5-point Sensor (Option)
Important Notes
The evaluator is located in the electrical cabinet door.
The length of the sensor cable may not be changed.
Adjustment by electrostatically charged persons can cause the amplifier
to malfunction.
All adjustments should be made with operating ground (no ground
conductor function) connected. The operating ground must be linked to
the metal casing of the melter along the shortest path. Do not connect
via ground conductor!
All potentiometers have 20 revolutions and no mechanical limit stop,
meaning no fixed end position. They can not be damaged by turning too
far.
6
5
4
3
2
1
7
8
9
10
11
12
13
14
15
17
16
LED (1)
LED (2)
LED (3)
LED (4)
LED (5)
Sensor cable colors black (bk)
−
green (gn)
−
blue (bl)
−
red (rd)
−
white (wh)
1 LED
Tank empty
(yellow)
2 LED
Tank level low
(yellow)
3 LED
Start filling
(yellow)
4 LED
Stop filling
(yellow)
5 LED
Tank overfilled
(yellow)
6 LED
Operating voltage
(green)
7 LED
Fault
(red)
8 LED
Sensor break
(red)
9 Potentiometer
P4
10 Potentiometer
P3
11 Power cable (bk)
12 Power cable (gn)
13 Power cable (bl)
14 Power cable (rd)
15 Power cable (wh)
16 Connection
Operating ground
17 Voltage supply (24V)
Summary of Contents for VersaBlue VB Series
Page 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...