Troubleshooting
6-28
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
LED’s of 5-point Sensor Evaluator
6
5
4
3
2
1
7
8
16
LED
Fault or mode
Sensor cable color
1
Yellow
On
Material covering 1st measuring point
Tank
empty
White (wh)
2
Yellow
On
Material covering 2nd measuring point
Tank level
low
Red (rd)
3
Yellow
On
Material covering 3rd measuring point
Start filling
Blue (bl)
4
Yellow
On
Material covering 4th measuring point
Stop filling
Green (gn)
5
Yellow
On
Material covering 5th measuring point
Tank
overfilled
Black: (bk)
6
Green
Power
On
Supply voltage present
−
7
Red
Fault LED 2
On
Same as the fault indication
Level sensor
defective
Switching sequence mixed up. Sensor cables
exchanged. Observe colors!
−
8
Red
Fault LED 1
Same as the fault indication
Level sensor failure
−
On
Broken wire at highest or lowest measuring point
−
Flashing
Broken wire at highest and lowest measuring
point or
Operating ground
BE
interrupted
−
Summary of Contents for VersaBlue VB Series
Page 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...