Troubleshooting
6-21
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Filling Valve (Option)
Problem
Possible Cause
Corrective Action
No material
No compressed air to control
module or compressed air set too
low
Connect compressed air and set to
correct value
Control module defective
Replace control module
Filling valve does not
heat
Temperature not set
Set on control panel of VersaBlue
melter or on filling unit
Plug not connected
Regulating via VersaBlue
Connect to corresponding hose
receptacle
Regulating via filling unit
Connect to hose receptacle
Temperature sensor(s) defective
Replace
Filling valve does not
reach set temperature
Heater cartridge(s) defective
Replace
Solenoid valve does not
switch
Solenoid valve is not triggered or
is defective
Trigger via customer’s PLC or
replace solenoid valve
Others
Problem
Possible Cause
Corrective Action
Leakage at pump shaft seal
Pump shaft seal is worn
Tighten the gland bolt
−
Replace pump
Material pressure too low,
output quantity too low
Gear pump is worn
Replace pump
Gear pump blocked
Processed material too cold
Correct temperature setting
(observe data sheet of material
manufacturer)
Foreign material in gear pump
Replace pump
Leakage at gun during
heatup phase
Safety valve does not open
(expansion pressure)
Replace safety valve
Continued...
Summary of Contents for VersaBlue VB Series
Page 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...