Technical Data
9-3
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Electrical Data
WARNING:
The unit is designed for only one operating voltage. Operate
only at the operating voltage shown on the ID plate.
Available operating voltages
200 V
AC
3-phase without neutral (
Delta
)
230 V
AC
3-phase without neutral (
Delta
)
400 V
AC
3-phase with neutral (star
−
WYE
)
400 V
AC
3-phase without neutral (
Delta
)
480 V
AC
3-phase without neutral (
Delta
)
Permissible voltage
deviations
Power supply:
"
10%
I/O:
"
10%
Operating voltage
frequency
50/60 Hz
Melter fuse protection
Refer to ID plate
Max. melter load
Refer to ID plate
Key-to-line
Max. input
0 to 10 V
DC
0 to 20 mA
4 to 20 mA
0 to 100 kHz