4. Select assignment!
Replacing motor controller
1. Switch off main contactor
and wait 3 min!
Replacing motor controller
New MC
Main
contactor
Repair
7-7
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
5. In this case: Touch key PUMP 2.
Exit the screen again by touching the door symbol.
6. Switch off the main contactor and wait 3 min.
7. Disconnect the operating voltage from MC 1, 2 and 3. Connect MC 4.
8. Switch on main contactor.
9. Select assignment. Touch key PUMP 4.
10. Switch off the main contactor and wait 3 min.
11. Reattach all motor controller connections. In this case: MC 1, 2 and 3.
12. Switch on main contactor.
All motor controllers are now assigned.
13. Exit the screen again by touching the door symbol.
NOTE:
The screen can not be exited until all of the motor controllers
have been assigned.
14. Switch melter off and on again with main switch.