Installation
3-13
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Digital inputs
Pin
Input
Function
11
0 V
24 V
Rising edge: Switch application group to control mode (input 1)
0 V
24 V
Falling edge: Switch application group to standby
or
Falling edge: Deactivate application group
(
Standby
or
Deactivate
is dependent on the function selected on the control panel,
refer to section
Operation, Working with Application Groups, Setup, Selecting Feature
12
Like pin 11 (input 2)
13
Like pin 11 (input 3)
14
Like pin 11 (input 4)
15
Line started / stopped
Pin 16 not assigned
NOTE:
Contact rating max. 24 V
DC
/2 A
Digital outputs
Pin
Contact
Function
17
Make
contact
Contact closed: Motor 1 running
Contact open: Motor 1 not running
18
19
Make
contact
Contact closed: Motor 2 running
Contact open: Motor 2 not running
20
21
Make
contact
Contact closed: Motor 3 running
Contact open: Motor 3 not running
22
23
Make
contact
Contact closed: Motor 4 running
Contact open: Motor 4 not running
24
25
24 V
DC
External (customer’s; to be connected by customer)
26
Make
contact
24 V: System ready
0 V: System not ready
27
Break
contact
24 V: No general alarm
−
warning
−
0 V: General alarm
−
warning
−
28
Break
contact
24 V: No general alarm
−
fault
−
0 V: General alarm
−
fault
−
Pin 29 not assigned
30
Make
contact
Contact closed: Pressure build-up completed
Contact open: Pressure build-up not completed
31
Make
contact
With option
Level display
Contact closed: Fill tank
Contact open: Do not fill tank
32
NOTE:
Pins 31 and 32 are not assigned with the options
Level control
and
Level
control with overflow protection
. Instead, there is the interface
Level control
that
triggers the filling valve.
Summary of Contents for VersaBlue VB Series
Page 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...