internal
external
+24 V
DC
0 V
DC
Installation
3-18
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Interface Level Control
NOTE:
Available only with the options with filling valve.
Component designation: XS3
Default bridges
Digital inputs/outputs
Pin
Input
Output
Function
1
−
24 V
DC
Internal voltage supply of separate overflow protection
2
−
0 V
DC
3
−
24 V
DC
/2 A
Fill tank
signal to filling valve
−
Additionally with level control with overflow protection
−
*)
Tank overfilled
(contact open when level is exceeded)
4
−
5
−
−
−
Only with level control with overflow protection
−
Reset (resets signal
Tank is overfilled
)
6
−
−
7
+24 V
DC
−
Voltage supply to filling valve
8
0 V
DC
−
9
−
24 V
DC
/ 2 A Fill tank
10
−
11
−
24 V
DC
/ 2 A
−
Only with level control with overflow protection
−
Tank overfilled
NOTE:
Potential-free changeover contact for evaluation by customer
12
−
13
−
Pin 14 to 16 not assigned
Summary of Contents for VersaBlue VB Series
Page 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...