Maintenance
5-19
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Safety Valve for Pneumatics
The safety valves, preset at the factory and lead sealed, prevent higher
pressurization than permitted of the subsequent pneumatic components.
When the factory settings are exceeded, compressed air audibly escapes.
NOTE:
The safety valves for the pneumatic options are located in the
melter tower.
Performance Check
The performance of the safety valve should be checked approx. every six
months. Turn the knurled screw until compressed air audibly escapes. If the
safety valve does not function properly, it should be cleaned. If it still does
not function, it must be replaced.
NOTE:
A defective safety valve may be replaced only with an original spare
part. Only the manufacturer may perform repairs to the safety valve!
Cleaning
Pollution that has penetrated fitting surfaces and conical nipples can be
removed by unscrewing the entire top piece
−
without changing the
minimum operating pressure. Use a sickle wrench to unscrew.
Summary of Contents for VersaBlue VB Series
Page 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...