Outputs
Inputs
Installation
3-12
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Interface Assignment
Interface Standard I/O
−
Standard Assignment
−
General Notes
To conform with a European standard regarding electro-magnetic
compatibility (EMC), only shielded cable may be connected. The cable
must
be connected to ground in compliance with the standard regarding
electromagnetic compatibility.
Inductive loads (e.g. solenoid valves) connected to the melter must be
equipped with a protective device (e.g. recovery diode) that disables the
inductive voltage generated when an inductive load is switched off.
The permitted voltage deviation is
10%.
In
Field bus
mode (option
Fieldbus communication
) the unit can not be
controlled via the interface.
Digital inputs
Pin
Input
Function
1
*
24 V
DC
Internal (melter)
2
*
0 V
DC
External (customer’s)
NOTE:
Customer connects his reference potential here, if 24 V
DC
is provided by
customer.
3
0 V
24 V
Rising edge: Heaters ON (main contactor closes)
0 V
24 V
Falling edge: Heaters OFF (main contactor opens)
4
24 V: All motors ON (collective enable)
0 V: All motors OFF
5
24 V: Enable
Motor 1
0 V: No
Motor 1
enable
6
24 V: Enable
Motor 2
0 V: No
Motor 2
enable
7
24 V: Enable
Motor 3
0 V: No
Motor 3
enable
8
24 V: Enable
Motor 4
0 V: No
Motor 4
enable
9
0 V
24 V
Rising edge: Switch on
Standby
0 V
24 V
Falling edge: Switch off
Standby
10
0 V
24 V
Rising edge: Key-to-line mode (for all motors)
0 V
24 V
Falling edge: Manual mode (for all motors)
*
selectable
Summary of Contents for VersaBlue VB Series
Page 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...