Replacing Pressure Sensor
CAN Bus Terminating Resistor
The last node on the CAN bus (e.g. a pressure sensor or electrical cabinet
VBCM
) must be equipped with a terminating resistor (120
W
).
1
3
4
2
120
W
6
4
5
Example with three pressure sensors
1 Motor controller
2 Connector
3 First pressure sensor
4 Second pressure sensor
5 Third pressure sensor
6 Terminating resistor
Procedure
1. Switch off the pressure sensor to be replaced (
P sensor 1
in the
example). Also refer to section
Operation
.
2. Wait until the ON/OFF key is no longer transparent.
3. Disconnect the pressure sensor from the CAN bus.
4. Connect CAN bus cable to new pressure sensor.
5. Refer to
Pressure Sensor Setup
in the section
Operation
for information
on how to proceed.
Example
NOTE:
If during work on the CAN bus errors occur that have no readily
apparent cause (red indication lamps) or the unit shuts down, switch the
melter off then on again with the main switch.
Summary of Contents for VersaBlue VB Series
Page 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Page 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...