Tank
Temperature
Enable/Disable
Set Point
Manifold
Hose 1
Applicator 1
OLED User Interface
28
Part 1128351_02
E
2020
Nordson Corporation
Managing Heated Zones
There are two types of heated zones:
S
Internal Zones
: Tank and the manifold
S
External Zones
: Connected hoses and applicators
Enabling/Disabling and Changing Zone Set Point
Temperatures
1. Navigate and select the zone you want to enable/disable or change its
set point temperature and press
>
on the Navigation pad.
2. Do the following to continue:
S
To Enable/Disable an external zone - Press the
on the Navigation pad
to toggle the zone to Enable or Disable. When done, press the
<
on the
Navigation pad to return to the previous screen.
S
To change the set point temperature, press the Up/Down keys on the
Navigation pad to select the zone you want to change its set point
temperature, then press
>
and enter the set point temperature you want.
When done, press the
.
Zone
Default
Minimum
Maximum
Internal Zones
177
_
C
(351
_
F)
40
_
C
(100
_
F)
204
_
C
(400
_
F)
External Zones
177
_
C
(351
_
F)
40
_
C
(100
_
F)
232
_
C
(450
_
F)
NOTES:
S
By default, internal zones are
enabled,
and all external zones are
disabled.
S
Select
Global Set Point
to make all zones (enabled or disabled) the
same set point temperature.
S
Internal zones (tank and manifold) cannot be disabled. You can only
change their set point temperatures.
S
Although there are two internal zones (tank and manifold), changing one
internal zone automatically changes the other. You cannot have two
different internal zone set point temperatures.
Summary of Contents for ProBlue Flex
Page 73: ...OLED User Interface 67 Part 1128351_02 E 2020 Nordson Corporation Figure 3 ATS PCA Board...
Page 129: ......
Page 130: ......