System Settings
Ready Delay
Temperature Settings
OLED User Interface
53
Part 1128351_02
E
2020
Nordson Corporation
Defining Ready Delay
Use
Ready Delay
to prevent the melter from immediately exiting out of
Heating
when the tank reaches its set point temperature, thereby allowing
enough time for adhesive to melt that is sufficient for production.
NOTE:
S
Regardless of a cold start, if Ready Delay is enabled, the melter will enter
Ready Delay if the manifold set point is less than 28
_
C (50
_
F) of its set
point. Enabling other external zones has no effect on Ready Delay.
1. Press the
on the Navigation pad to toggle
Ready Delay
to Enabled or
Disabled. The default is Disabled.
2. Select
Time,
press
>
, and enter the amount of time you want the melter
to continue to heat, thereby preventing the melter from immediately
exiting out of
Heating.
This provides time for enough adhesive for
production to melt in the tank. The default and minimum is 1 minute, and
the maximum is 60 minutes. When done, press
.
3. Press
<
to return to the
Setback Settings
menu or
to return to the
Home
screen.
Bypassing Ready Delay
Once the melter enters into Ready Delay, the following pop up screen
appears.
Countdown Timer
Exit out of Ready Delay
Keep melter in
Ready Delay, but
clear this popup
NOTE:
If you press
to remove the pop-up message, you can still see the
countdown by navigating to System Settings | Temperature Settings and
viewing the Ready Delay option. The countdown timer appears until the
Ready Delay time elapses.