OLED User Interface
63
Part 1128351_02
E
2020
Nordson Corporation
Defining Adhesive Flow Monitoring Alarms
Use the Teach mode to automatically calculate the
Target Add-On
and
Products to Average
values.
NOTE:
S
Make sure the
Adhesive Flow Monitoring
option is enabled. (
Home |
System Settings | Flow Settings)
1. Go to
Home | System Settings | Flow Settings
and select
Monitor
Alarm Settings
and select or enter the following information.
Setting
Description
Default
Min
Max
Alert Alarm
Enables or disables the system from
monitoring and generating flow Alert
alarms
Note:
When an Alert alarm is
generated, production continues, but
attention may be needed.
Disabled
N/A
N/A
Low Alert Threshold
How much lower the add-on weight
(mg) can be from the Target Add-On
value before an Alert alarm is
generated.
.2 * Target
add on
value
.05 *
Target
add on
value
.5 * Target
add on
value
High Alert Threshold
How much higher the add-on weight
(mg) can be from the Target Add-On
value before an Alert alarm is
generated.
.3 * Target
add on
value
.05 *
Target
add on
value
.5 * Target
add on
value
Alert Delay Count
The number of consecutive
out-of-tolerance products allowed
before the system considers them
defective and generates an Alert
alarm.
4
1
15
Stop Alarm
Enables or disables the system from
monitoring and generating flow Stop
alarms.
Note:
When a Stop alarm is
generated, production is halted.
Immediate attention is required.
Disabled
N/A
N/A