Setting Up Maintenance Reminders
Use the Maintenance system to monitor and remind you when to inspect,
perform maintenance or replace the following components.
Component
What you need
to do
Based on
Default / hrs
Minimum / hrs
Maximum / hrs
Piston Pump
Lubricate the
pump
Pump On hours
500
160
6000
Hydraulic Filter
Change filter
2000
480
6000
Fill System
Filter
Change the air
filter
500
40
6000
Service Alert
Check System
500
40
500
General
Purpose
User-defined
1000
160
30000
Inline Filter
Change filter
Pump On hours
2000
160
6000
Tank
Drain and flush
Heater On
hours
2000
480
6000
Hose
Replace
Hose Heating
hours
6000
2000
30000
Module
Run System
State hours
1000
480
30000
Solenoid
1000
480
30000
Nozzle
1000
160
30000
NOTES:
S
Use the BBconn Cloud Application or the touch screen version to
Add, Modify, or Delete maintenance reminder hours and snooze
settings.
S
If you perform maintenance or replace a component before receiving
a maintenance reminder, you must reset the maintenance reminder.
See
Resetting or Snoozing Maintenance Notifications
for more
information.
S
System Maintenance
must be enabled to receive maintenance
notifications, as well as to view maintenance status and history
reports. See
Managing the Maintenance System
for more
information.
The following sections detail how to:
S
Enable or disable the Maintenance System
S
Enable or disable maintenance reminders on a per-component basis
S
Reset or Snooze Maintenance Notifications
S
View maintenance history
S
Export the maintenance report