Defining Tank-Only Level Sensing Settings
This section of the manual details the following Level Sensing Settings for
tank-only melters.
S
Enable/Disable Low Level Alert and Settings
S
Empty Stop
S
Enable/Disable Lid Open Alert and Settings
Enabling/Disabling Low Level Alerts and Settings
Use the Level Sensing settings to fine-tune the low/empty adhesive
messaging.
TIP:
S
You can also assign a system output for Tank Low and connect that to a
light tower.
1. Press the
on the Navigation pad to toggle
Low Level Alert
to Enabled
or Disabled. The default is Enabled.
2. Select
Low Level Threshold
, press
>
, and enter a value representing
the percentage of adhesive left in the tank before receiving a low level
message. The default is 25%, the minimum is 10%, and the maximum is
30%. When done, press the
on the Navigation pad to accept changes.
3. Press
to return to the
Home
screen, or press
<
to return to the
System Settings menu.
NOTE:
S
Press
on the OLED panel to clear and reset any Alert, Fault, or
Stop condition.