OLED User Interface
24
Part 1128351_02
E
2020
Nordson Corporation
Switching the Master Heater and Pump Controls On/Off
When you power-up the melter, by default, the Master Heaters and Pump
controls are switched Off. You must manually switch them On.
System Status
Master Heater Control
Master Pump Control
S
To toggle the Master Heater control On, Press the
master control
button. The LED illuminates. Press the master control button again to
switch it Off.
However, you can make use of the
Heaters on Upon Startup
(
System
Settings | Global Settings
) to change this behavior.
S
To toggle the Master Pump control On, press
The Pump LED
flashes.
S
If AutoPump is enabled, then the pump button will flash, indicating that
the Master Pump control will be toggled On as soon as system
temperature ready is achieved. If you press the Master Pump Control
button again, AutoPump becomes disabled, although only for this one
time. When the system Temperature Ready is achieved, the Master
pump Control remains Off. In this case, pushing the Master Pump Control
button again will switch the Master Pump Control On, since system
temperature ready has already been achieved.
S
If you press the Master Pump control button with AutoPump disabled and
before the system is not at Temperature Ready, AutoPump is
momentarily Enabled and the Pump button flashes.