OLED User Interface
121
Part 1128351_02
E
2020
Nordson Corporation
Fill System Alarms
(contd)
Alarm
Type
Short Description
Details
Troubleshooting Tips
Alert
Low Tank Level
Adhesive level in melter is
abnormally low. The system
should have filled before
reaching this point.
Check the following;
S
Check for loose or
disconnected level
sensor ground wires.
S
Check for low adhesive
Level in adhesive
storage bin.
S
Check for clogged
adhesive in adhesive
storage bin, hose or
transfer pump.
S
Check for clogged
exhaust air filter.
S
Check for low transfer
pump air pressure.
Stop
Tank Empty
The tank level is at a
critically low level. The Pump
has been turned off to
prevent air from entering the
system.
Both the Fill and Pump are
automatically switched Off.
Check the following:
S
Low adhesive level
S
Failed solenoid
S
Clogged adhesive
storage container, hose,
and exhaust air filter
S
Check for low air
pressure at the adhesive
storage container.