OLED User Interface
122
Part 1128351_02
E
2020
Nordson Corporation
Electronic Pressure Adjust Alarms
The following table details the troubleshooting tips to resolve Alert and Fault
conditions.
Alarm
Type
Short Description
Details
Troubleshooting Tips
Alert
High Pressure Alert
Pressure exceeds the High
Pressure Threshold.
Check or do the following:
S
Increase pressure
threshold.
S
Check supply air
pressure.
S
Check for defective
transducer.
Alert
Low Pressure Alert
Pressure is below Low
Pressure Threshold.
Check air supply air input or
leaking airline.
Alert
Pressure below detectable
range
Pressure input indicates the
pressure is below the
sensing range.
Check air supply to the
system for disconnected air
input or leaking airline.
Alert
Pressure Control Valve
Disconnected
No pressure adjust device is
detected, and is required for
run-up or remote pressure
adjustments.
Install or reconnect pressure
adjust device.
Alert
Pressure Sensor
Disconnected
The system has detected
that the air pressure sensor
is disconnected from the
Low Voltage Control Board.
Reconnect sensor.
Alert
Minimum System Pressure
System pressure is below
the minimum required
system pressure.
Increase input air pressure.
Fault
Alert
Maximum System Pressure
System pressure is above
the maximum required
system pressure.
Reduce input air pressure
Fault
Summary of Contents for ProBlue Flex
Page 73: ...OLED User Interface 67 Part 1128351_02 E 2020 Nordson Corporation Figure 3 ATS PCA Board...
Page 129: ......
Page 130: ......