Monitoring Operation
9-13
Part 1056418-07
E
2019 Nordson Corporation
Node Error Codes
Errors 65, 68: Check Ethernet connections. Usually means controller is
unplugged or off.
Errors 66, 67, 69
−
75: Programming errors. Call Nordson Technical Support.
Errors 129
−
132: Noise on circuit. Check connections. Check to ensure
Ethernet cables are not parallel to high voltage or VFDs.
Errors 161
−
164: Programming errors or hardware error. Call Nordson
Technical Support.
Error Code
Description
65
I/O error
66
Port open error
67
Already open
68
Connection error
69
Remote closed connection
70
Library error
71
Port already bound
72
Listen failed
73
File descriptors exceeded
74
No permission
75
Port not available
129
Checksum error
130
Frame error
131
Reply error
132
Reply time-out
161
Modbus exception
162
Illegal address
163
Illegal value
164
Slave device failure
CAN Network Status
The CAN network is the iControl internal network. The iControl system
communicates with the gun control cards over the CAN network. The
Prodigy iControl system uses the CAN network to communicate with the
pump control cards and the manual gun controllers.
Touch the CAN Network Status Button to open the CAN Network Status
screen. Nordson service representatives can use this screen to diagnose
problems with the CAN network.
Summary of Contents for Encore iControl 2
Page 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Page 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Page 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Page 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Page 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...