Standard System Configuration
3-6
Part 1056418-07
E
2019 Nordson Corporation
Smart Flow Mode Enable
Smart Flow mode can be used with all spray guns that use venturi-type
pumps, except the Tribomatic automatic gun.
It cannot be used for
Prodigy or Encore HD guns
.
In this mode, you set Total Air (powder velocity) and Flow Air % (powder
flow) setpoints. The controller automatically adjusts flow-rate and atomizing
air flows to the pump based on the setpoints.
For a full description of how to use the Smart Flow mode, refer to
Section 5,
Spray Gun Preset Settings
.
Digital Input Card Select
Two different digital input cards are used in the iControl system. Both cards
have a manufacturer part number located in the upper left corner.
1. Open the iControl enclosure and locate the card part number.
2. Select the correct part number on the Guns/Input Card Configuration
screen.
S
When the AX 754 card is installed and selected, the Conveyor
Indicator will light when the interlock is connected and the conveyor
is running.
S
When the PCLD782 card is installed and selected, the Conveyor
Indicator will NOT light when the interlock is connected and the
conveyor is running.
Touch the
Help
button for additional information.
Manual Mode Lockout
This feature is used when a single iControl console is used with multiple
booths where 1 or more booths may be offine at any time. This feature
prevents manual triggering of the guns in all booths, so that the guns in an
offline booth cannot triggered accidentally.
The feature must first be enabled. Then the type of relay used must be
chosen. It is recommended that the NC (normally closed) option be used,
and all interlocks wired in series, so that any one booth that is offline with its
exhaust fan off will break the circuit and prevent manual operation of any
booths.
Summary of Contents for Encore iControl 2
Page 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Page 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Page 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Page 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Page 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...