Standard System Configuration
3-5
Part 1056418-07
E
2019 Nordson Corporation
Default Gun Type
Select a default gun type.
NOTE: If you are using HDLV feed pumps, you must select
Prodigy/Encore HD guns even if you are actually using a different type
of gun.
Normally, the iControl system reads the gun type from the resistors in the
gun cables and displays the gun icon on the gun control screens. If the
exhaust fan is off, the gun control cards are powered off and the iControl
system cannot read the gun type from the hardware. Instead, the system
uses the default gun type for all guns. This allows you to set up or edit
Spray Preset settings while the exhaust fan is off.
HDLV Pump Controller Version
Select the version of HDLV pump controller firmware used in your system.
Version 2.0 is required to use the pump Fast Mode, which allows the pump
to operate faster and push more powder out to the spray gun. When fast
mode is set for a preset, all guns using that preset use fast mode.
NOTE:
You cannot have a mix of version 1 and version 2 pump firmware in
your system; an alarm will occur if a mix of version 1 and 2 is detected.
Spectrum HD
Select Spectrum HD if your system is a Spectrum HD system with Easy
Clean Hopper. This equipment is only sold in the EU.
Number of Guns per Console
Set the number of guns connected to the iControl consoles:
Systems with Encore, Sure Coat, Tribomatic, or Versa-Spray guns:
Standard systems control 16 guns per console. Set CM for guns 1
−
16, and
if the system has more than 16 guns, set CS for the remainder of the guns
(17
−
32).
Systems with Prodigy/Encore HD guns:
A Prodigy or Encore HD iControl
master console controls 32 guns. Set CM for guns 1
−
16, and if the system
has more than 16 guns, set CS for the remainder of the guns (17
−
32).
Flow Air Upper Limit
Use this setting to limit the air flow settings for all guns. The iControl system
supports values that may not be appropriate for the number of guns and the
air volume and pressure available. Limiting the value prevents flow related
error messages when the flow settings are too high and the system cannot
attain the commanded value.
Summary of Contents for Encore iControl 2
Page 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Page 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Page 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Page 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Page 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...