Monitoring Operation
9-11
Part 1056418-07
E
2019 Nordson Corporation
Network Status
Use the Network Status screen and Node Status screens to help diagnose
problems with the devices (nodes) on the Remote I/O network, such as the
in/out positioners or positioner scanners.
To open the Network Status screen:
Touch the
System Configuration
button on the Main screen to
open the System Configuration screen.
Touch the
Network Configuration
button on the System
Configuration screen to open the Network Status screen:
Node Status Buttons
(Ethernet Network)
CAN Network
Status Button
Figure 9-10 Network Status Screen
Ethernet Node Status
The node status buttons indicate the operating status of the nodes on the
Ethernet network:
S
Green: Nodes are communicating with the network.
S
Red: Nodes are not communicating with the network.
NOTE:
Only configured nodes will have a button on this screen.
Touching a
Node Status Button
opens the Status screen for that node.
See Figure 9-11. This screen is used for diagnosing problems with the
network and the nodes.
Summary of Contents for Encore iControl 2
Page 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Page 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Page 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Page 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Page 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...