Reciprocator Preset Settings
7-6
Part 1056418-07
E
2019 Nordson Corporation
Reciprocator Preset Percent-Adjust Settings
See Figure 7-4. Reciprocator Preset Percent-Adjust settings change the
current spray gun preset flow-rate and atomizing air settings by a
percentage at points above and below the part edges.
NOTE:
Percent Adjust is an additive variable. Reciprocator Preset
Percent-Adjust settings are added or subtracted from Reciprocator Stroke
Length Percent Adjust settings, Global Percent-Adjust settings, and
Conveyor Speed Percent-Adjust settings.
For Spray Gun percent adjust setting instructions, refer to Percent Adjust
Functions in
Section 8
,
Operation
. Refer also to
Section 4,
Positioner/Reciprocator Configuration
for Reciprocator Stroke Length
Percent Adjust.
Variable mode
: The
On/Off Up/Down
settings are the distances from the
edge that the Flow-Rate and Atomizing air percent adjust settings are
turned on and off. The On/Off Up/Down settings can be positive or
negative. Positive settings turn the adjustment on BEFORE the part edge
and off AFTER the part edge. Negative settings turn the adjustment on
AFTER the part edge and off BEFORE the part edge.
Fixed mode:
The
On/Off Up/Down
settings are measured from
reciprocator Home and must always be positive.
The
Percent-Adjust Flow-Rate and Atomizing
air settings are the percent
by which the current setting is changed. These settings can be positive or
negative. Percent adjust can be
Enabled or Disabled
for each
reciprocator. Touch the field to toggle the status. When enabled an X is
displayed in the field.
Flow-Rate
On Up
Atomizing
Off Down
On Down
Off Up
Enable/Disable
Variable Mode
% On
% Off
% On
% On
% Off
% Off
Fixed Mode
% On
% Off
% On
% On
% Off
% Off
On Down
Off Up
Off Down
On Up
Reciprocator Home (0)
Figure 7-4
Reciprocator Preset Settings
−
Variable Mode
Summary of Contents for Encore iControl 2
Page 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Page 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Page 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Page 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Page 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...