Reciprocator Preset Settings
7-5
Part 1056418-07
E
2019 Nordson Corporation
Variable Mode Settings
Reciprocator Speed
can be set for
Variable, No
Synchronization mode only.
Top and Bottom Overtravel
settings are the distance above and below a
part that the reciprocator travels before turning around when a part is in
front of the guns. Positive overtravel settings extend the spray pattern,
turning the guns on BEFORE the part edge and off AFTER the part edge.
Negative overtravel settings restrict the spray pattern, turning the guns on
AFTER the part edge and off BEFORE the part edge.
If no part is present, then the configured turn-around limits apply.
Top
Overtravel
Bottom
Overtravel
Speed
(No Sync Mode
Only
Top Turn-Around (Configuration Setting)
Bottom Turn-Around (Configuration Setting)
Top Overtravel
Bottom Overtravel
Reciprocator Home (0)
Fixed Mode,
Conveyor
Synchronization
Fixed Mode,
No Conveyor
Synchronization
Top Turn-Around (Configuration Setting)
Bottom Turn-Around (Configuration Setting)
Top Overtravel
Bottom Overtravel
Reciprocator Home (0)
Variable Mode
Positive Overtravel Settings
Extended Spray
Variable Mode
Negative Overtravel Settings
Restricted Spray
Conveyor Travel
Conveyor Travel
Figure 7-3
Reciprocator Preset Settings
−
Variable Mode
Summary of Contents for Encore iControl 2
Page 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Page 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Page 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Page 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Page 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...