MAINTENANCE
39
SpeedScrub Rider 331140 (9- 2013)
FaST SYSTEM MAINTENANCE (FaST Model)
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off
machine, and remove key.
Every 1000 hours replace the water filter and air
filter located in the FaST detergent injector. Order
filter kit p/n 9003009.
1. To access the detergent injector assembly,
lower the scrub head. The injector assembly
is located on top of the scrub head.
new photo
Disk Model
Cylindrical Brush
Model
2. Remove the injector assembly from the pinch
clamps.
3. Replace the water and air filter. An 8mm hex
wrench is required to install the new water filter.
Water Filter
(50 Mesh/Brown)
Air Filter
(50 Mesh/Brown)
FaST SUPPLY HOSE CONNECTOR
The FaST supply hose connector is located below
the FaST- PAK holder. Soak the connector in
warm water if detergent buildup is visible. When a
FaST- PAK carton is not installed, store the
supply hose connector on the storing plug to
prevent the hose from clogging.