OPERATION
20
SpeedScrub Rider 331140 (9- 06)
CIRCUIT BREAKERS
Circuit breakers
are resettable electrical circuit
protection devices that stop the flow of current in
the event of a circuit overload. Once a circuit
breaker is tripped, allow breaker to cool and then
press the reset button to manually reset the
breaker.
If the overload that caused the
circuit breaker
to
trip is still there, the
circuit breaker
will continue to
stop current flow until the problem is corrected.
The
circuit breakers
are located inside the battery
compartment next to the hour meter.
The chart shows the
circuit breakers
and the
electrical components they protect.
Circuit
Breaker
Rating
Circuit Protected
CB1
5 A
Instrument Panel - power
CB2
15 A
Accessories
FUSES
The
fuse
is a one-time protection device designed
to stop the flow of current in the event of a circuit
overload. The 100 A fuse is located inside the
battery compartment near the hourmeter. It
protects the propel circuit.
NOTE: Always replace the fuse with a fuse of the
same amperage.
HAZARD LIGHT SWITCH (OPTION)
The Hazard Light Switch operates the optional
hazard light.