OPERATION
17
SpeedScrub Rider 331140 (03- 2015)
Do not operate machine in areas where the
ambient temperature is above 43
_
C (110
_
F). Do
not operate scrubbing functions in areas where
the ambient temperature is below freezing 0
_
C
(32
_
F).
The maximum rated incline for scrubbing with the
machine is 7%. The maximum rated incline during
transport of the machine is 19.25%.
EMERGENCY STOP BUTTON
The
Emergency Stop Button
halts all power to the
machine in case of an emergency. Press the
button to halt the machine power. To restart the
machine, turn the
Emergency Stop Button
to the
right. Then turn the on/off switch to the off position
and then to the on position.
NOTE
:
This button should not be used for normal
stopping as premature wear to the parking brake
may occur.
HOUR METER
The
hour meter
records the number of hours the
machine has been powered on. This information
is useful for servicing the machine. It is located
under the seat.
ec- H2O
SYSTEM INDICATOR LIGHT
The ec- H2O system indicator light will not turn on
until the machine starts scrubbing.
ec-H2O NanoClean Models
(ec-H2O models labeled ec-H2O NanoClean)
ec-H2O SYSTEM
INDICATOR LIGHT
CODE
CONDITION
Solid green
Normal operation
Blinking green/red
Water conditioning
cartridge expired.
Replace cartridge.
Solid or blinking* red Contact Service Center
If the ec-H2O system indicator light begins to
blink green/red, the water conditioning cartridge
needs to be replaced (See ec-H2O NanoClean
WATER CONDITIONING CARTRIDGE
REPLACEMENT).
*Verify if cleaning detergent was added to solution
tank. If ec-H2O system was operated with
cleaning detergent, drain solution tank, add clear
water and operate the ec-H2O system until the
indicator light code clears.
ec-H2O Models
(ec-H2O models manufactured before ec-H2O
NanoClean models)
ec-H2O
SYSTEM
INDICATOR LIGHT
CODE
CONDITION
Solid green
Normal operation
Blinking red
Flush
ec-H2O
module
Solid red
Contact Service Center
If an alarm sounds and the ec- H2O system
indicator light begins to blink red, the ec- H2O
module must be flushed to resume ec- H2O
operation (See ec-H2O MODULE FLUSH
PROCEDURE).