4.5 Sequence Operation
BP4620
4-33
Sequence control
Sequence operation control is described below. Sequence control is indicated enclosed between
pointed brackets (<>) below.
Table 4-16. Sequence Control
<Start>
Changes the status to Run status.
In the case of the Idle status, Step 1 is jumped to at the same time as <Start>, and the
sequence starts.
In the case of the Hold status, the sequence resumes from the point in time when <Hold>
is executed.
If the status changes to the <Hold> status with [Step termination], the status changes to
[Jump step] at the same time as <Start> and the sequence restarts.
<Hold>
The status changes to the Hold status.
<Stop>
The status changes to the Idle status.
The status immediately changes to regular output step.
At this time, the value at <Stop> is held for the [Output parameter]of the regular output
step.
<Branch>
The step changes to the step specified with [Branch step].
The status changes [Branch step] from the output status at the point in time when
<Branch> was executed.
<Hold>
<Start>
STEP 2 setting
Last value
Step time
Step 1
Step 2
Time
Step 3
Output parameter
Figure 4-14. Example of Sequence Operation When <Start> Is Executed from Hold Status
Step 1
Step 2
Step 5
Output parameter
Step 2 settings
Last value
Step time
Branch step 5
Time
Step 5 settings
End value of previous step
<Branch>
Figure 4-15. Example of Sequence Operation During <Branch>
Summary of Contents for BP4620
Page 1: ...NF Corporation BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual nbn Austria GmbH...
Page 2: ...DA00016125 006 BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual...
Page 3: ......
Page 15: ......
Page 16: ...BP4620 1 1 1 OVERVIEW 1 1 General 1 2 1 2 Features 1 2 1 3 Principle of Operation 1 4...
Page 21: ......
Page 39: ......
Page 165: ...6 1 Error Messages BP4620 6 4 Figure 6 1 Protective Function Related Error Display Examples...
Page 171: ......
Page 187: ......
Page 206: ...BP4620 9 1 9 INITIAL SETTING LIST 9 1 Initial Setting List 9 2...
Page 211: ......
Page 213: ......