8.4 Signal Sources
BP4620
8-6
8.4 Signal
Sources
The signal source can be selected from among internal signal source, external signal source, and
internal signal external signal source.
Internal signal source
DC
Amplitude setting range:
115 V
(0.01 V resolution)
(CV mode)
20 A
(0.001 A resolution)
(CC mode)
Amplitude setting accuracy:
(|0.5% of setting value| + 0.2 V)
(CV mode,
AC 0 V, 12
resistance load, DC only, 23
5
C)
(|0.5% of setting value| + 0.06 A)
(CC mode,
AC 0 A, DC only, 23
5
C)
Superimposed AC
Waveform: Sine,
square,
arbitrary (16 types)
Frequency setting range:
1 Hz to 100 kHz (0.1 Hz resolution)
Frequency accuracy:
100 ppm
Amplitude setting range:
0 to 120 Vp-p
(0.1 Vp-p resolution)
(CV mode)
0 to 60 Ap-p
(0.01 Ap-p resolution)
(CC mode)
Amplitude setting accuracy:
(0.5% of setting value + 0.2 Vp-p)
(CV mode,
DC 0 V, AC only 500 Hz sine wave, 23
5
C)
(0.5% of setting value + 0.06 Ap-p)
(CC mode,
DC 0 A, AC only 500 Hz sine wave, 2
resistance load,
23
5
C)
External signal input
Gain: 100
(100 V/1 V), in phase
(CV mode)
20
(20 A/1 V), in phase
(CC mode)
Gain accuracy:
5% (1 kHz)
Input impedance:
10 k
Ω
Non-destructive max. input voltage:
5 V
Input terminal:
BNC connector (front panel)
Frequency range:
DC to 200 kHz
Summary of Contents for BP4620
Page 1: ...NF Corporation BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual nbn Austria GmbH...
Page 2: ...DA00016125 006 BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual...
Page 3: ......
Page 15: ......
Page 16: ...BP4620 1 1 1 OVERVIEW 1 1 General 1 2 1 2 Features 1 2 1 3 Principle of Operation 1 4...
Page 21: ......
Page 39: ......
Page 165: ...6 1 Error Messages BP4620 6 4 Figure 6 1 Protective Function Related Error Display Examples...
Page 171: ......
Page 187: ......
Page 206: ...BP4620 9 1 9 INITIAL SETTING LIST 9 1 Initial Setting List 9 2...
Page 211: ......
Page 213: ......