5.2 Program Message List
BP4620
5-5
Table 5-3. Sequence Related
(1/2)
Header Function Max.
ValueMin. Value Resolution Setting Query
SLEN?
Specifies sequence length
Fixed to 255
STPN
Specifies step number
255 1 1
SEXP
Step execution
parameters
1st parameter
DC voltage/DC current
2nd parameter
DC voltage/DC current operation
type
0: CONST/1: KEEP/2:
SWEEP
3rd parameter
Superimposed AC voltage/
superimposed AC current
4th parameter
Superimposed AC voltage/
superimposed AC current operation
type
0: CONST/1: KEEP/2:
SWEEP
5th parameter
Frequency
6th parameter
Frequency operation type
0: CONST/1: KEEP/2:
SWEEP
7th parameter
Waveform
2 to 17: ARB1 to ARB16
8th parameter
Waveform operation type
0: CONST/1: KEEP
9th parameter
Step sync output
0: (0,0)/1: (0,1)/
2: (1,0)/3: (1,1)
10th parameter
Step sync output operation type
0: CONST/1: KEEP
STRP
Step transition
parameters
1st parameter
Step time mode
Fixed to 0
2nd parameter
Step time
3rd parameter
Step end phase enable/disable
0: Disable/1: Enable
4th parameter
Step end phase
Fixed to 0 deg
5th parameter
Step termination
0: Continue sequence
1: Enter Idle status
2: Enter Hold status
6th parameter
Jump step
0:
Go to next step number
1 to 255: Step number
Summary of Contents for BP4620
Page 1: ...NF Corporation BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual nbn Austria GmbH...
Page 2: ...DA00016125 006 BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual...
Page 3: ......
Page 15: ......
Page 16: ...BP4620 1 1 1 OVERVIEW 1 1 General 1 2 1 2 Features 1 2 1 3 Principle of Operation 1 4...
Page 21: ......
Page 39: ......
Page 165: ...6 1 Error Messages BP4620 6 4 Figure 6 1 Protective Function Related Error Display Examples...
Page 171: ......
Page 187: ......
Page 206: ...BP4620 9 1 9 INITIAL SETTING LIST 9 1 Initial Setting List 9 2...
Page 211: ......
Page 213: ......