4.13 Measurement Function
BP4620
4-86
4.13 Measurement
Function
The BP4620 has a function for measuring the output voltage and output current (DC value and P-P
value of each). Since the measured values are displayed in the LCD’s measurement value window, the
output status can be monitored.
The specifications of the measurement function are as follows.
DC output voltage measurement (Measures the AC+DC average. However, AC+DC
must be within
200 V.)
Full scale:
200 V (resolution: 0.1 V)
Measurement accuracy:
0.5 V (within DC
115 V, AC 0 V)
DC output current measurement (Measures AC+DC average. However, AC+DC must
be within
40 A.)
Full scale:
40 A (resolution: 0.01 A)
Measurement accuracy:
0.2 A (DC
20 A, AC 0 A)
AC output voltage measurement (Measures max. value of AC+DC
Min. value of
AC+DC. However, AC+DC must be within
200 V.)
Full scale:
400 Vp-p (resolution: 1 Vp-p)
Measurement accuracy:
2 Vp-p (DC 0 V, 120 Vp-p, 500 Hz)
Measurement frequency band:
10 kHz/
3 dB
AC output current measurement (Measures max. value of AC+DC
Min. value of
AC+DC. However, AC+DC must be within
40 A.)
Full scale:
80 Ap-p (resolution: 0.1 Ap-p)
Measurement accuracy:
2Ap-p (DC 0 A, 60 Ap-p, 500 Hz)
Measurement frequency band:
10 kHz/
3 dB
Figure 4-31. Measurement Value Display Example
If measurement over-range occurs, “-----” is displayed in the numerical value field.
Summary of Contents for BP4620
Page 1: ...NF Corporation BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual nbn Austria GmbH...
Page 2: ...DA00016125 006 BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual...
Page 3: ......
Page 15: ......
Page 16: ...BP4620 1 1 1 OVERVIEW 1 1 General 1 2 1 2 Features 1 2 1 3 Principle of Operation 1 4...
Page 21: ......
Page 39: ......
Page 165: ...6 1 Error Messages BP4620 6 4 Figure 6 1 Protective Function Related Error Display Examples...
Page 171: ......
Page 187: ......
Page 206: ...BP4620 9 1 9 INITIAL SETTING LIST 9 1 Initial Setting List 9 2...
Page 211: ......
Page 213: ......