8.12 External Control I/O
BP4620
8-10
8.12 External Control I/O
External control operation mode
Enabled or disabled (Status output is always on.)
Control input
Input level:
High level: +4.0 V or higher
Low level: +1.0 V or lower
Non-destructive max. input:
+10 V/
5 V
Input impedance:
Pulled up to +5 V with 47 k
Detection cycle:
2ms
Control items
Output OFF:
Output off at fall
Output ON:
Output on at fall
Sequence start:
Sequence start at fall
Sequence stop:
Sequence stop at fall
Hold input:
Hold at fall
Branch input 0, 1:
Branch start at fall
Status output
Output level:
0/+5 V (open)
Output impedance:
100
Switching cycle:
0.1ms
Status items
Power on/off status:
0-OFF, 1-ON
Output on/off status:
0-OFF, 1-ON
Overload:
0-Normal,
1-Overload
Software busy:
0-Normal, 1-Busy
Sequence operation step sync output 0, 1
Terminal
D-sub 25-pin multiconnector (rear panel, female, M2.6 screw)
Summary of Contents for BP4620
Page 1: ...NF Corporation BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual nbn Austria GmbH...
Page 2: ...DA00016125 006 BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual...
Page 3: ......
Page 15: ......
Page 16: ...BP4620 1 1 1 OVERVIEW 1 1 General 1 2 1 2 Features 1 2 1 3 Principle of Operation 1 4...
Page 21: ......
Page 39: ......
Page 165: ...6 1 Error Messages BP4620 6 4 Figure 6 1 Protective Function Related Error Display Examples...
Page 171: ......
Page 187: ......
Page 206: ...BP4620 9 1 9 INITIAL SETTING LIST 9 1 Initial Setting List 9 2...
Page 211: ......
Page 213: ......