7.8 Performance Test
BP4620
7-11
7.8 Performance
Test
Performance test
Performance testing is performed as part of preventive maintenance in order to prevent
performance degradation of the BP4620. To facilitate execution, this test is performed under
conditions that partially differ from the specifications, as the test items, used measuring
equipment, and load condition are limited for the sake of convenience. If more extensive testing
is required, contact NF Corporation or an NF Corporation sales representative.
Performance testing should be performed as part of acceptance inspection, periodic inspection,
performance verification following repair of the BP4620, etc.
If, as the result of performance testing, the BP4620 is found not to meet its specifications, repair
is necessary. In this case, contact NF Corporation or an NF Corporation sales representative.
Verification prior to performance testing
Prior to performance testing, check the following items.
Is the power supply voltage within the rated range?
Is the ambient temperature within 23
5
C?
Is the ambient relative humidity within the range of 20 to 70%RH?
Is there any condensation?
Has the BP4620 been warmed up for 30 minutes or longer?
Preparations prior to performance testing
Use a cable with a cross section of 2 mm
2
or more and a length of 2 m or less for connecting the
load.
The setting contents of each test item include items that can be changed after performing setting
initialization (by executing RESET in SYSTEM menu). After checking the setting contents,
switch on the output.
Maximum output voltage test using CV mode external signal input
Load: 3
resistance load
Measurement connection: Connect the output of the external oscillator to the external signal input
of the BP4620. Then connect an AC voltmeter and distortion meter to the output terminal of the
BP4620 and measure the voltage and distortion.
Settings: After performing setting initialization, set the operation mode and external oscillator
frequency according to the following table.
Judgment: Gradually increase the output voltage of the external oscillator from 1 Vp-p (the
output voltage of the BP4620 is 100 Vp-p, 35.4 Vrms), and if the output voltage of the BP4620
immediately before the distortion exceeds 1% or overload occurs falls within the rated range
indicated in the following table, the operation is judged to be normal.
Operation Mode Setting
External Oscillator Frequency
Rated Range
CV-EXT
50 Hz
42.43 Vrms or higher
500 Hz
42.43 Vrms or higher
Maximum output current test using CC mode external signal input
Load: Shorted via current shunt resistor.
Measurement connection: Connect the output of the external oscillator to the external signal input
of the BP4620. Then connect the detection voltage of the current shunt resistor to an AC
voltmeter and distortion meter, and measure the current and distortion.
Settings: After performing setting initialization, set the operation mode and external oscillator
frequency according to the following table.
Judgment: Gradually increase the output voltage of the external oscillator from 1.6 Vp-p (the
output voltage of the BP4620 is 32 Ap-p, 11.3 Arms), and if the output voltage of the BP4620
immediately before the distortion exceeds 1% or overload occurs falls within the rated range
Summary of Contents for BP4620
Page 1: ...NF Corporation BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual nbn Austria GmbH...
Page 2: ...DA00016125 006 BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual...
Page 3: ......
Page 15: ......
Page 16: ...BP4620 1 1 1 OVERVIEW 1 1 General 1 2 1 2 Features 1 2 1 3 Principle of Operation 1 4...
Page 21: ......
Page 39: ......
Page 165: ...6 1 Error Messages BP4620 6 4 Figure 6 1 Protective Function Related Error Display Examples...
Page 171: ......
Page 187: ......
Page 206: ...BP4620 9 1 9 INITIAL SETTING LIST 9 1 Initial Setting List 9 2...
Page 211: ......
Page 213: ......