4.5 Sequence Operation
BP4620
4-39
Table 4-17. PROGRAM Screen Item List
Item Name
Item
Operation
STEP Step
No.
Specifies the step number to be set.
Setting range: 1 to 255
TIME Step
time
Specifies the duration of the specified step.
Setting range:
0.0001 s to 999.9999 s
Setting
resolution: 0.0001
s
DC VOLT
DC voltage
Sets the DC voltage in the CV mode.
Setting
range:
115.00 V to 115.00 V
Setting
resolution: 0.01
V
DC CUR
DC current
Sets the DC current value in the CC mode.
Setting
range:
20.000 A to 20.000 A
Setting
resolution: 0.001
A
DC voltage/DC current
operation type
Sets the type of transition to the specified DC voltage value and DC
current value. The type of transition can be selected from the following
three.
CONST:
Output of the specified value
KEEP:
Output of the last value of the previous step
SWEEP:
Output started with the last value of the preceding step,
with linear sweep outputting the specified value at the end
of the step
AC VOLT
Superimposed AC voltage
Sets the superimposed AC voltage value in the CV mode.
Setting range:
0.0 Vp-p to 120.0 Vp-p
Setting range:
0.1 Vp-p
AC CUR
Superimposed AC voltage
Sets the superimposed AC voltage value in the CC mode.
Setting range: 0.00 Ap-p to 60.00 Ap-p
Setting range: 0.01 Ap-p
Superimposed AC
voltage/superimposed AC
current operation type
Sets the type of transition to the specified superimposed AC voltage
value and superimposed AC current value. The type of transition can be
selected from the following three.
CONST:
Output of the specified value
KEEP:
Output of the last value of the previous step
SWEEP:
Output started with the last value of the preceding step,
with linear sweep outputting the specified value at the end
of the step
FREQ Frequency
Sets the superimposed AC frequency.
Setting range:
1.0 Hz to 100000.0 Hz
Setting
resolution: 0.1
Hz
Frequency operation type
Sets the type of transition to the specified frequency. The type of
transition can be selected from the following three.
CONST:
Output of the specified value
KEEP:
Output of the last value of the previous step
SWEEP:
Output started with the last value of the preceding step,
with linear sweep outputting the specified value at the end
of the step
WAVE
Waveform
Selects the arbitrary waveform to be output.
Setting range:
ARB1 to ARB16
Frequency operation type
Selects the type of transition to the specified waveform. The type of
transition can be selected from the following three.
CONST:
Output of the specified waveform
KEEP:
Output of the waveform of the previous step
Summary of Contents for BP4620
Page 1: ...NF Corporation BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual nbn Austria GmbH...
Page 2: ...DA00016125 006 BIPOLAR DC POWER SUPPLY BP4620 Instruction Manual...
Page 3: ......
Page 15: ......
Page 16: ...BP4620 1 1 1 OVERVIEW 1 1 General 1 2 1 2 Features 1 2 1 3 Principle of Operation 1 4...
Page 21: ......
Page 39: ......
Page 165: ...6 1 Error Messages BP4620 6 4 Figure 6 1 Protective Function Related Error Display Examples...
Page 171: ......
Page 187: ......
Page 206: ...BP4620 9 1 9 INITIAL SETTING LIST 9 1 Initial Setting List 9 2...
Page 211: ......
Page 213: ......