SECTION 3 -- FIELD OPERATION
3--75
Operate the control lever (2) to retract the cylinder
(L), and the programming light will cease to flash and
remain on. Hold the lever until the cylinder has
completed the retract cycle and then return to the
neutral position. After the second phase has been
programmed the light will remain on.
After the second phase has been completed and the
lever has been returned to neutral, the programme
will be automatically stored.
Repeat the above sequence to programme the
remaining control levers if required.
130
Programming of the control lever can be performed
in either sequence, extend/retract, retract/extend or
for one movement only, extend or retract. The
maximum allowable time span for any timed
operation is 30 seconds.
Programming a Single Acting Service
To programme a single acting service carry out the
same set--up procedure as previously described for
a double acting service.
With the programme light flashing, move the remote
valve lever from neutral to the extend position (R).
When the cylinder has extended to the desired
position, manually return the lever to the neutral
position. To store the setting, depress the timer
switch. In single acting mode the sequence will NOT
be automatically stored.
A single acting service can be programmed to
operate in either extend or retract modes.
NOTE:
When using a timed sequence for a single
acting service i.e. programmed in extend mode only,
the retract mode will not function until the programme
sequence has been deleted.
If the control lever is moved to the float position no
timed programme is possible and the control lever
must be returned to neutral manually.
131
Summary of Contents for T6010 DELTA
Page 1: ...OPERATOR S MANUAL T6010 T6020 T6030 T6050 T6070 Delta and Plus Tractors ...
Page 6: ...BLANK ...
Page 28: ...SECTION 1 GENERAL INFORMATION AND SAFETY 1 22 NOTES ...
Page 280: ...SECTION 3 FIELD OPERATION 3 146 NOTES ...
Page 366: ...SECTION 5 FAULT FINDING 5 12 NOTES ...
Page 368: ...SECTION 6 VEHICLE STORAGE 6 2 NOTES ...
Page 400: ...SECTION 8 SPECIFICATIONS 8 24 NOTES ...
Page 402: ...SECTION 9 1ST 50 HOUR SERVICE SHEETS 9 2 ...
Page 404: ...SECTION 9 1ST 50 HOUR SERVICE SHEETS 9 4 ...
Page 410: ...SECTION 10 INDEX 10 6 ...
Page 412: ...sblank ...