SOPHO
IP 5000/SOPHO IP6000
Command Reference Guide
80
% connection refused by remote host!
speed
Syntax
speed speed-value
undo speed
View
User interface view
Parameter
speed-value
: Transmission rate in bps.
Description
Using the
speed
command, you can set the transmission rate of a user
interface. Using the
undo speed
command, you can restore the default
transmission rate of the user interface.
By default, the transmission rate is 9600bps.
Only when the serial interface works in asynchronous flow mode will the
configuration be effective.
The transmission rates supported by asynchronous serial interfaces include:
■
300bps
■
600bps
■
1200bps
■
4800bps
■
9600bps
■
19200bps
■
38400bps
■
57600bps
■
115200bps
Example
Set the transmission rate of the user interface to 19200bps.
[NEC-PHILIPS-ui-vty0]
speed 19200
stopbits
Syntax
stopbits { 1.5 | 1 | 2 }
undo stopbits
View
User interface view
Parameter
1.5
: Sets the stop bit to 1.5.
1
: Sets the stop bit to 1.
2
: Sets the stop bit to 2.
Description
Using the
stopbits
command, you can set the stop bit of a user interface. Using
the
undo stopbits
command, you can restore the default stop bit of the user
interface.
By default, the stop bit is set to 1.