SOPHO
IP 5000/SOPHO IP6000
Command Reference Guide
34
xxxxxx.yyyyyy, with xxxxxx being the 32 high bits and yyyyyy the 32 low bits of
the passed milliseconds.
date
: Current system date and time, in the form of “yyyy/mm/dd-hh:mm:ss” in
Chinese and “mm/dd/yyyy-hh:mm:ss” in English.
none
: No time stamp.
info-center trapbuffer
Description
Using the
info-center timestamp
command, you can set the time stamp format
for the output debugging/trapping/logging information. Using the
undo info-
center timestamp
command, you can cancel the current configuration.
By default, the date time stamp is used in information of all types.
Example
Set the time stamp format for traps to boot.
[NEC-PHILIPS]
info-center timestamp trap boot
info-center trapbuffer
Syntax
info-center trapbuffer [ channel { channel-number | channel-name } | size
buffersize ] *
undo info-center trapbuffer [ channel | size ]
View
System view
Parameter
channel
: Sets the channel for outputting information to the trapbuffer.
channel-number
: Channel number ranging 0 to 9. That is, system has 10
channels.
channel-name
: Channel name.
size
: Sets trapbuffer size.
buffersize
: Size of the trapbuffer (the information entries that can be
accommodated).
Description
Using the
info-center trapbuffer
command, you can enable the trapbuffer and
set the output channel number and trapbuffer size. Using the
undo info-center
trapbuffer
command, you can cancel the current configuration.
By default, information output to trapbuffer is allowed and the trapbuffer size is
256.
Only when the info-center has been enabled will this command become
effective.
By setting a trapbuffer size, you can make the router output information to the
trapbuffer.
For related commands, see
info-center enable, display info-center, and
display info-center trapbuffer.