SOPHO
IP 5000/SOPHO IP6000
Command Reference Guide
156
Description
Using the
e1 set frame-format
command, you can configure the frame format
for an E1 line. Using the
undo e1 set frame-format
command, you can restore
the default setting.
By default, the frame format no-crc4 is used for E1 line.
Only if an E1 line is working in framed format (which can be set by using the
undo e1 unframed command) can this command be configured.
For related command, see
e1 unframed
.
Example
Configure the first E1 line on the E3 interface to adopt the frame format crc4.
[NEC-PHILIPS-E3 1/0/0]
e1 1 set frame-format crc4
e1 set loopback
Syntax
e1 line-number set loopback { local | remote }
undo e1 line-number set loopback
View
CE3 interface view
Parameter
line-number
: E1 line number in the range of 1 to 16.
local
: Enables E1 line to perform local loopback.
remote
: Enables E1 line to perform remote loopback.
Description
Using the
e1 set loopback
command, you can set the loopback mode of an E1
line on an E3 interface. Using the
undo e1 set loopback
command, you can
disable the E1 line to loop back.
By default, E1 lines are disabled to loop back.
If an E1 line encapsulated with PPP has been set to perform loopback, it is
normal for the state of the link layer protocol to be reported as DOWN.
Example
Set the loopback mode of the first E1 line on the E3 interface to local.
[NEC-PHILIPS-E3 1/0/0]
e1 1 set loopback local
e1 shutdown
Syntax
e1 line-number shutdown
undo e1 line-number shutdown
View
CE3 interface view
Parameter
line-number
: E1 line number in the range of 1 to 16.
Description
Using the
e1 shutdown
command, you can shut down an E1 line on the CE3
interface. Using the
undo e1 shutdown
command, you can enable the E1 line.