SOPHO
IP 5000/SOPHO IP6000
Command Reference Guide
174
rate
: Specify maximum rate, in the range of 64~2312.
Description
Using the
shdsl rate
command, you can specify maximum rate at SHDSL
interface or just select auto-negotiation mode. Using the
undo rate
command,
you can restore the default setting.
By default, auto is selected.
Example
Restore the auto mode at the interface.
[NEC-PHILIPS-Atm1/0/0]
undo shdsl rate
shdsl snr
Syntax
shdsl snr threshold
undo snr
View
ATM interface view
Parameter
threshold
: In the range of 5~30. By default, it is 25.
Description
Using the
shdsl snr
command, you can specify SNR (signal-to-noise ratio)
value at an SHDSL interface. Using the
undo snr
command, you can restore
the default value.
Example
Restore SNR value to the default value.
[NEC-PHILIPS-Atm1/0/0]
undo shdsl snr
shdsl margin
Syntax
shdsl margin { disable | value }
undo margin
View
ATM interface view
Parameter
disable
: Ignores target margin in link negotiation.
value
: Sets target margin value, in the range of 0~10.
Description
Using the
shdsl margin
command, you can enable SNR target margin. Using
the
undo margin
command, you can restore the default value.
By default, the SNR target margin is 3.
Example
Set shdsl margin to 8.
[NEC-PHILIPS-Atm1/0/0]
shdsl margin 8