physical-mode
Syntax
physical-mode { sync | async }
View
Serial interface view
Parameter
sync
: Sets the synchronous/asynchronous serial interface to work in
synchronous mode.
async
: Sets the synchronous/asynchronous serial interface to work in
asynchronous mode.
Description
Using the
physical-mode
command, you can set the operating mode of a
synchronous/asynchronous serial interface.
By default, the synchronous/asynchronous serial interface is working in
synchronous mode.
Example
Set the synchronous/asynchronous serial interface to work in asynchronous
mode.
[NEC-PHILIPS-Serial0/0/0]
physical-mode async
4.4
Fundamental CE1/PRI Interface Configuration Commands
channel-set
Syntax
channel-set set-number timeslot-list range
undo channel-set set-number
View
CE1/PRI interface view
Parameter
set-number
: The number of the channel set formed by bundling the timeslots on
the interface, which is in the range of 0 to 30.
range
: The number of the timeslots that are bundled, which is in the range of 1
to 31. When specifying the timeslots to be bundled, you can specify a single
timeslot by specifying a number, a range of timeslots by specifying a range
between number1-number2, or several discrete timeslots by specifying
number1, number2-number3.
Description
Using the
channel-set
command, you can bundle some timeslots of a CE1/PRI
interface into a channel-set. Using the
undo channel-set
command, you can
remove the specified timeslot bundle.
By default, no timeslots are bundled into channel-sets.
A CE1/PRI interface in CE1/PRI mode is physically divided into 32 timeslots
numbered from 0 through 31.
In actual applications, all the timeslots except timeslot 0 can be bundled into
multiple channel-sets and the system will automatically create a serial interface