277
CHAPTER 14 A/D CONVERTER
(2) A/D conversion operation in software start
When bit 6 (TRG) and bit 7 (CS) of A/D converter mode register (ADM) are set to 0 and 1, respectively, the
A/D conversion starts on the voltage applied to the analog input pins specified with bits 1 to 3 (ADM1 to
ADM3) of ADM.
Upon termination of the A/D conversion, the conversion result is stored in the A/D conversion result register
(ADCR) and the interrupt request signal (INTAD) is generated. After one A/D conversion operation is started
and terminated, the next A/D conversion operation starts immediately. The A/D conversion operation
continues repeatedly until new data is written to ADM.
If data with CS set to 1 is written to ADM again during A/D conversion, the converter suspends its A/D
conversion operation and starts A/D conversion on the newly written data.
If data with CS set to 0 is written to ADM during A/D conversion, the A/D conversion operation stops
immediately.
Figure 14-9. A/D Conversion by Software Start
Remarks 1. n = 0, 1, ... , 7
2. m = 0, 1, ... , 7
Conversion Start
CS=1, TRG=0
A /D Conversion
ADCR
INTAD
ANIn
ANIn
ANIm
ANIn
ANIm
ANIm
ANIn
ANIn
ADM Rewrite
CS=1, TRG=0
ADM Rewrite
CS=0, TRG=0
Conversion suspended
Conversion results are
not stored
Stop
Summary of Contents for PD78052
Page 2: ...2 MEMO ...
Page 8: ...8 MEMO ...
Page 16: ...16 MEMO ...
Page 36: ...36 MEMO ...
Page 158: ...158 MEMO ...
Page 174: ...174 MEMO ...
Page 240: ...240 MEMO ...
Page 260: ...260 MEMO ...
Page 340: ...340 MEMO ...
Page 392: ...392 MEMO ...
Page 438: ...438 MEMO ...
Page 482: ...482 CHAPTER 20 REAL TIME OUTPUT PORT MEMO ...
Page 510: ...510 MEMO ...
Page 524: ...524 MEMO ...
Page 560: ...560 MEMO ...
Page 576: ...576 MEMO ...
Page 598: ...598 MEMO ...
Page 602: ...602 MEMO ...